Ordering information
AC-DC Power Supplies Enclosed type
PBA15F
PBA/PBW
PBA/PBW
PB
1
A
15
2
3
F
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
-O
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is acquired
[5V, 12V, 24V])
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer externally
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA15F-3R3
9.9
3.3V 3A
PBA15F-5
15
5V 3A
PBA15F-9
15.3
9V 1.7A
PBA15F-12
15.6
12V 1.3A
PBA15F-15
15
15V 1A
PBA15F-24
16.8
24V 0.7A
PBA15F-48
16.8
48V 0.35A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
PBA15F-3R3
PBA15F-5
PBA15F-9
PBA15F-12
PBA15F-15
PBA15F-24
PBA15F-48
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
ACIN 100V 0.30typ (Io=100%) 0.4typ (Io=100%)
ACIN 200V 0.15typ (Io=100%) 0.2typ (Io=100%)
50/60 (47 - 440) or DC
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV] *6
LOAD REGULATION[mV] *6
0 to +50C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-10 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
68typ
74typ
75typ
75typ
77typ
75typ
75typ
68typ
75typ
77typ
78typ
80typ
78typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
9
12
15
24
48
3
3
1.7
1.3
1
0.7
0.35
20max
20max
36max
48max
60max
96max
192max
40max
40max
100max
100max
120max
150max
240max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
200max
120max
120max
150max
150max
150max
150max
250max
160max
160max
180max
180max
180max
180max
300max
50max
50max
90max
120max
150max
240max
480max
60max
60max
120max
150max
180max
290max
600max
20max
20max
36max
48max
60max
96max
192max
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
39.0 - 53.0
3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48
15.00 - 15.60
24.00 - 24.96
48.00 - 49.92
Works over 105% of rated current and recovers automatically
4.00 - 5.25
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
58.0 - 65.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter *4) *7
31X78X85mm [1.22X3.07X3.35 inches] (without terminal block) (WXHXD) / 200g max (with cover : 235g max)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
PBA/PBW-4
PBA/PBW-4
*5
*6
*7
*
*
*
Please contact us about safety approvals for the model with option.
Please contact us about dynamic load and input response.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.