HWS50-1500/HD Series
Single Output Industrial Power Supplies
Features
Limited Lifetime Warranty
-10 to +71°C Operation (-40°C start up)
Universal Input (85 - 265VAC)
Conformally coated pcbs
Class 1 Div 2 option (/RYHD suffix)
Wide range AC Input
Key Market Segments & Applications
Specifications
Model
Input Voltage range (47-63Hz)
Input Current (Typ)
(1)
Inrush Current
(1)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (60Hz)
Remote Sense
Indicator
Remote On/Off
Parallel operation
DC Good
Remote Adjust (PV)
Operating Temperature
and Derating (operation to
+74°C - contact factory)
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
(2)
Isolation Resistance
Vibration (non operating)
Shock (in packaging)
Safety Agency Approvals
Line Dip
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
A
A
V
ms
mA
°C
°C
g
in
yrs
HWS50
HWS100
HWS150
HWS300
HWS600
HWS1000 HWS1500
85-265VAC or 120-370VDC**
85-265VAC or 120-330VDC** (No DC input for HWS1500)
0.7 / 0.35
1.3 / 0.65
1.9 / 0.95
4.1 / 2.1
8.1 / 3.9
13.5 / 7
19 / 10
14 / 2
20 / 4
Meets EN61000-3-2
<0.02%/°C
>104%
Yes (See table on page 2)
20
<0.5mA
<0.75mA
<1.2mA
≤1.5mA
No
Yes
Green LED = ON
No
Yes (Isolated from output)
No
Single wire connection (5 units max)
No
Yes
No
Yes (3)
HWS50-150: -10°C to +71°C, (-10 ~+50°C: 100%, +60°C: 60%, +71°C: 20%)
HWS300-1500: -10°C to +71°C, (-10 ~+50°C: 100%, derate linearly to 50% load from +50 to +71°C)
Guaranteed start up at -40°C (see specification sheets on website for details and derating)
-40 to +85°C
Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH
Convection
Internal fan
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC
MIL-STD-810F 514.5 Category 4, 10 (HWS1500 Cat 4, figure 514.5C-1)
MIL-STD-810F 516.5 Category I, VI (HWS1500 <196.1m/s2)
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B (HWS1500 Class A)
IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5, -8 (Level 4), -11
280
450
500
1000
1600
3200
3800
1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 5x3.2x9.5
5x3.25x11
Limited lifetime warranty (See TDK-Lambda’s terms & conditions)
(1) 100/200VAC input
(2) HWS300-600 2.5kVAC Input to ground
(3) 1-6V program voltage input to adjust output 20-120% (typical) of
nominal. See instruction manual for details & models with this feature.
(*) Class 1 Div 2 option (/RYHD suffix
(**) Safety certified for AC input only
H W S 50- 150/H D N o t r e c o m m e n ded for new desi gns, see HW S -A web p a ge
1-800-526-2324 • www.us.tdk-lambda.com/lp/
63
Disclaimer: us.tdk-lambda.com/lp/legal.htm