Panel Meters and Controllers
Panel Meter Modular
Series EDM 35
• Modular digital panel meter, 3 1/2-digit
• Indicating or controlling current, voltage,
resistance, temperature, tacho or frequency.
• Easy programming
• Programmable hysteresis and time delay
(up to 2 setpoints)
• Data hold
• Peak/valley function
• Password protection of programming parameters
• Stock-saving - several ranges on each input module
• IP 65 (front)
• Optional hardware lock of programming
• Optional high-efficiency red or green display
Product Description
Ordering Key
The EDM 35 is a 3 1/2-digit,
modular digital panel meter
where input and output modules can be combined to suit
many applications. Scaling
and setpoints are fully programmable and the program-
ming itself is very user-friendly. Furthermore, the EDM 35
includes peak/valley function
and password protection. The
housing is easy to mount and
ensures a protection degree
of IP 65.
Main unit
Range
Power supply
Relay output
Signal output
Options
Range AC Voltmeters:
V1A: 0 to 199.9 mV
V2A: 0 to 1.999 V
V3A: 0 to 19.99 V
V4A: 0 to 199.9 V
V5A: 0 to 600 V *
Range Ohmmeters:
R1D: 0 to 199.9 Ω
R2D: 0 to 1.999 kΩ
R3D: 0 to 19.99 kΩ
R4D: 0 to 199.9 kΩ
Range DC Ammeters:
A1D: -199.9 to +199.9 µA
A2D: -1.999 to +1.999 mA
A3D: -19.99 to +19.99 mA
A4D: -199.9 to +199.9 mA
A5D: -1999 to +1999 mA
A6D: -5.00 to +5.00 A
A7D: -10.00 to +10.00 A
Signal Output:
X: None
1: 4 to 20 mA
2: 0 to 20 mA
4: 0 to 10 V
5: Transducer power
supply 12 VDC
6: Transducer power
supply 24 VDC
Contact factory for other output signals
Options:
XX:
None
CX: High eff. red display
DX: Green display
XP:
Program lock
01-99: Special options
(assigned by factory)
EDM35V1D41XXX
Type Selection
Range DC Voltmeters:
V1D: -199.9 to +199.9 mV
V2D: -1.999 to +1.999 V
V3D: -19.99 to +19.99 V
V4D: -199.9 to +199.9 V
V5D: -600 to +600 V *
* Nominal voltage according to IEC 60664-1.
The measuring range includes 15% tolerance equal to 690 V.
Range AC Ammeters:
A1A: 0 to 199.9 µA
A2A: 0 to 1.999 mA
A3A: 0 to 19.99 mA
A4A: 0 to 199.9 mA
A5A: 0 to 1999 mA
A6A: 0 to 5.00 A
A7A: 0 to 10.00 A
Range Thermometers:
Pt 100:
P1C:
-100.0 to 199.9°C
P2C:
-100 to 850°C
P1F:
-148.0 to 199.9°F
P2F:
-148 to 392°F
P3F:
-148 to 1562°F
Thermocouple Type J:
-JC:
-100 to 760°C
-JF:
-148 to 1400°F
Thermocouple Type K:
-KC:
-100 to 1250°C
-KF:
-148 to 1999°F
Relay Output:
0: None
1: 1 Relay
2: 2 Relays
Power Supply:
3: 12 to 48 VDC
4: 230 VAC
5: 115 VAC
6: 48 VAC
7: 24 VAC
Specifications are subject to change without notice (27.10.99)
Range Frequency Meters:
F1X*: 5.0 to199.9 Hz
F2X*: 10.0 to 1999 Hz
*
Replace X with:
A for Namur input
B for NPN, PNP
& Contact input
C 600 VAC input
1