Signal
Signal Relays
AXICOM
FP2 Relay
n Telecom/signal
relay (dry circuit, test access, ringing)
line 14x9mm (.551x.354”)
n Switching current 2A
n 2 form C bifurcated contacts (2 CO)
n High sensitivity results in low nominal power consumption, 80mW
for high sensitive, 140mW for sensitive version
n High mechanical shock resistance, up to 300g functional, up to
1500g survival
n Slim
Typical applications
Communications equipment linecard application (ringing and test access),
PABX, voice over IP, office equipment, measurement and control equipment,
automotive equipment as CAN bus, keyless entry, speaker switch, medical
equipment, consumer electronics, set top boxes, HiFi.
Coil Data
Approvals
UL 508 File No. E 111441, UL 60950,
Technical data of approved types on request
Contact Data
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current, 85°C
Switching Power
Contact material
Contact style
Minimum switching voltage
Thermoelectrical potential
Initial contact resistance
Frequency of operation, without load
Operate time
Set/reset time
Release time
without diode in parallel
with diode in parallel
Bounce time
Electrical endurance
at 12V / 10mA
at 6V / 100mA
at 60V / 500mA
at 30V / 1000mA
at 30V / 2000mA
UL contact rating
Mechanical endurance
Z
2 form C (CO)
220VDC, 250VAC
2A
2A
60W, 62.5VA
AgNi, gold-covered
bifurcated contact
100μV
<10µV
<50mΩ at 10mA, 20mV
50 operations/s
typ. 2ms, max. 4ms
typ. 2ms, max. 4ms
typ. 2ms, max. 4ms
typ. 4ms, max. 6ms
typ. 1ms, max. 3ms
typ. 5x107 operations
typ. 1x107 operations
typ. 5x105 operations
typ. 1x106 operations
typ. 2x105 operations
50VDC / 2A - 100W
50VAC / 2A - 100W
30VDC / 2A - 60W
typ. 100x106 operations
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
polarized
2 to 24VDC
125°C
< 125K/W
Coil versions, monostable
Coil
Rated Operate Limiting Release
Coil
Rated coil
code voltage voltage Voltage voltage
resistance
power
VDC VDC VDC VDC
Ω±10%
mW
Standard version, monostable
06
3
2.10
6.60
0.30
64
140
04
4.5
3.15
9.90
0.45
145
140
0
9
5
3.50
11.00
0.50
178
140
05
6
4.20
13.20
0.60
257
140
10
9
6.30
19.80
0.90
574
140
02
12
8.40
26.40
1.20
1028
140
12
24
16.80
44.30
2.40
2880
200
13
48
33.60
72.30
4.80
7680
300
High sensitive version, monostable
High sensitive version, monostable
21
3
2.10
8.70
22
4.5
3.15
13.10
23
5
3.50
14.60
24
6
4.20
17.50
25
9
6.30
24.20
26
12
8.40
35.00
27
24
16.80
52.80
28
48
36.00
77.60
0.30
113
80
0.45
353
80
Telecom-, Signal and RF Relays
0.50
313
80
0.60
450
80
FP2 Relay
0.90
1013
80
1.20
1800
80
2.40
4114
140
4.80
8882
260
Coil Operating Range
All figures are given for coil without pre-energization, at ambient temperature +23°C.
80 mW
140 mW
200 mW
3.4
Max. DC load breaking capacity
3.2
3
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.8
2.6
DC voltage [VDC]
Coil Voltage [U/Unom]
2.4
=
=
Uop. min. =
2.2
2
1.8
Urel. min. =
1.6
1.4
1.2
Unom. nominal coil voltage
1
0.8
0.6
Uop. min.
Urel. min.
0.4
0.2
0
-60
DC current [A]
-40
-30
-20
-10
0
10
Catalog and product data is subject to the
2.6
terms of the disclaimer and all chapters of
2.4
the ‘Definitions’ section, available at
http://relays.te.com/definitions
2.2
2.0
]
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
-50
20
30
40
50
60
70
80
90
100 110 120
Ambient Temperature [°C]
nom
10-2012, Rev. 1012
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Unom
Umax
1.8
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
260 mW
subject to change.
300 mW
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
1