SBR20200R
VOLTAGE 200V
20 .0AMP Schottky Barrier Rectifiers
Elektronische Bauelemente
RoHS Compliant Product
A suffix of "-C" specifies halogen & lead-free
TO-247(TO-3P)
.638(16.20)
.605(15.38)
.144(3.65)
.128(3.25) DIA.
FEATURES
.204(5.20)
.181(4.60)
.319(8.10)
.303(7.69)
.244(6.20)
.228(5.8)
* Low forward voltage drop
* High current capability
* High reliability
* High surge current capability
* Epitaxial construction
.881(22.38)
.812(20.63)
30
.122(3.1)
.110(2.8)
.846(21.50)
.728(18.50)
MECHANICAL DATA
.177(4.50)
.153(3.90)
.050(1.30)
.045(1.10)
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Lead: Lead solderable per MIL-STD-202,
method 208 guaranteed
* Polarity: As Marked
* Mounting position: Any
.223(5.66)
.207(5.26)
P IN 1
* Weight: 2.24 grams(Approximately)
.027(0.70)
.019(0.48)
+
P IN 3
.095
(2.4)
C ASE
P IN 2
Dimens ions in inches and (millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
SYMBOL
UNITS
VRRM
VRSM
Maximum Average Forward Rectified Current
(Per Device)
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage (IF = 10 Amps,TF= 25 C, per leg)
Maximum Instantaneous Forward Voltage (IF = 10 Amps,TF= 125 C, per leg)
Maximum DC Reverse Current
Ta=25 oC
o
Ta=125 C
Voltage Rate Of Chance (Rated VR)
Operating Temperature Range
Storage Temperature Range
V
V
200
V
VF
10
20
A
IFSM
(Per Leg)
200
200
VDC
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
Maximum DC Blocking Voltage
at Rated DC Blocking Voltage
Typical Junction Capacitance (Note1)
Typical Thermal Resistance (Note 2)
SBR20200R
180
A
VF
0.92
0.80
V
IR
0.02
5
mA
CJ
RθJA
250
1.5
dv/dt
10000
-50 ~ +150
-65 ~ +175
TJ
TSTG
pF
C/W
o
V/us
C
C
NOTES:
1. Measured at 1MHz and applied reverse voltage of 5.0V D.C.
2. Thermal Resistance Junction to Case.
http://www.SeCoSGmbH.com
01-Jun-2006 Rev. A
Any changing of specification will not be informed individual
Page 1 of 2