T102
ENGINEERING DATA SHEET
TIME DELAY RELAY
1PNO (SSO)
Time delay relay on operate or on release
Fixed or adjustable timing delay
Contact arrangement
1 PNO
Power supply
Direct current
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
400 mAmps / 28 Vdc
Weight
< 7 grams
Dimensions of case
20.6mm x 10.4mm x 7mm max
Tin plated hermetically sealed metal can.
CONTACT ELECTRICAL CHARACTERISTICS
Nominal voltage
28Vdc
Contact rating
0.4 A
NUMBERING SYSTEM
Options
T102 - A
E - 1001
Basic series designation__________________________|
|
|
|
1-Types Of Operation (A,B,D,F,U,W)________________________|
|
|
2-Temperature Range And Timing Accuracy (J,K,P)________________|
|
3-Timing Range (4 digits) __________________________________________|
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 4/06
- 45 -
Page 1 of 4
MOUNTING STYLES AND TERMINAL TYPES
T102
20.6 MAX
7 MAX
15.24
±0.2
Ø0.8
10.16 ±0.2
5.8
5.08±0.2
2
1
8
7
3
5.08±0.2
±0.1
4
5
6
10.4 MAX
Dimensions in mm
Tolerances unless otherwise specified ±0.25mm
SCHEMATIC DIAGRAM/TERMINAL LAYOUT
1
2
R.P.P.
7
3
8
6
TIME DELAY
5
4
OUTPUT 1 : OPERATING VOLTAGE
OUTPUT 7 : TEST OUTPUT, DO NOT CONNECT
OUTPUT 3 : POSITIVE CONTROL, ONLY AVAILABLE ON
T102-DX AND T102-FX
OUTPUT 5-6 : EXTERNAL RESISTOR FOR OPERATION CODES
B, F AND W
OUTPUT 4 : GROUND
OUTPUT 2-8 : LOAD
RPP : REVERSE POLARITY PROTECTION
TIMING RANGE
ADJUSTABLE
Code 1001:
Code 1002:
Code 1003:
Code 1004:
(For operation code B, F and W)
0.1 to 1 second
Rx = (T / to -1) x 100kohm
1 to 10 seconds
10 to 100 seconds
100 to 1000 seconds
where Rx in kohms T: desired time in seconds,
to: time measured with Rx = 0.
Example to determine Rx value for a T time of 5 seconds:
Choose code 1002; measure time with
Rx = 0 (for example : to = 1 s); calculate Rx = (5/1 - 1) x 100000
Theoretical resistance: Rx = 400 kohms
FIXED
The timing code consists of 4 digits. To determine this code, convert the value to milliseconds
value. Use the first 3 digits of this value and add a fourth digit to indicate the number of
zeros which must follow the three digits to show complete milliseconds value.
Examples: 250 ms --> Code 2500
Date of issue: 3/06
300 s --> Code 3003
- 47 -
Page 3 of 4