2013-5장
2012.11.22 6:46 PM
페이지200
G4-1.25G(Mac 1) JETPDF 2400DPI 175LPI
T
LARGE ALUMINUM ELECTROLYTIC CAPACITORS
LM
Lug Terminal Type
Series
Solvent Proof
WV≦100V
·Lug terminal series
·Suited for use in power supplies and industrial controls
·Complied to the RoHS directive
Item
Characteristics
Operating temperature range
Capacitance tolerance
Leakage current max.
WV< 350 : -40 ~ +85° WV≧350 : -25 ~ +85°
C,
C
±20% at 120Hz, 20°
C
I=3 CV (μ (after 5 minutes)
A)
Capacitance > 1000μ : tanδ
F
increases by 0.01 for each 1000μ from below value.
F
Dissipation factor max.
(at 120Hz, 20°
C)
WV
tanδ
16
0.35
25
0.30
80~350
0.20
400~450
0.25
Less than specified value
Within ±20% of initial value
Less than 200% of specified value
Leakage current
Capacitance change
tanδ
Load life
(after application of the rated
voltage for 2000 hours at 85°
C)
35~63
0.25
After 1000 hours no load test, leakage current, capacitance and tanδ same as load life value.
are
The measurement shall be performed at 20° by the KS C 6035 clause 5.4.
C
Shelf life (at 85°
C)
Unit : mm
● DRAWING
Insulating sleeve
●Terminal
ØD+α
max.
Safety vent
L+β
max.
Bottom plate
+
P±1
-
● TERMINAL
For solder tag
51
Ø3
4.5
2.5
Code
LC
3
LA
25.4
30
35
40
51
10
10
14
18
18
α
4.8
13.0
8.0
2.6
4.5
Dimensions
ØD
P
40
8
1
2
β
13.0
≦35
4
ØD
2
3
Ø2
LD
● FREQUENCY COEFFICIENT OF PERMISSIBLE RIPPLE CURRENT
WV
Frequency
~ 100
160 ~ 250
315 ~
200
50Hz
120Hz
300Hz
1kHz
10kHz≦
0.85
0.85
0.85
1.00
1.00
1.00
1.06
1.20
1.15
1.15
1.25
1.20
1.20
1.45
1.40