M220
ENGINEERING DATA SHEET
RELAY - NONLATCH
4 PDT, 5 AMP
Polarized, non latching hermetically sealed relay
4 PDT
Contact arrangement
Coil supply
Direct current
Qualified to
MIL-R-83536/5 and /6
CECC16101-028
CECC16303-804
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
5 Amps / 28 Vdc or 115 Vac 400 Hz
Weight
27 grams max
Dimensions max.
of case in mm
20.6 x 16.3 x 20.6
Hermetically sealed, corrosion resistant metal can.
APPLICATION NOTES:
001
007
APPLICABLE SOCKET:
S220
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
100,000 cycles
20,000 cycles
100,000 cycles
100,000 cycles
50 cycles
400,000 cycles
Contact rating per
pole and load type
Load Current in Amps
@28 Vdc
@115 Vac, 400 Hz
@115/200 Vac, 400 Hz 3Ø
resistive load
inductive load (L/R=5ms)
motor load
lamp load
5
3
2
1
5
5
3
1
5
5
3
1
resistive overload
20
30
30
at 25% rated resistive load
Featuring LEACH© power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 10/10
- 69 -
Page 1 of 4