HK-A Series
Single Output 115VAC Input Industrial Power Supplies
Features
u 3 Year Warranty
u Small size
u Approved to UL & CSA (cUL)
u 85 - 132VAC Input, 47-440Hz
u ±10% output adjustment
u Adjustment potentiometer
u Low profile
Key Market Segments & Applications
Specifications
Model
Input Voltage range
Inrush Current (100VAC)
Temperature Coefficient (Typ)
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ at 100VAC)
Remote Sense
LED Indicator
Operating Temp (no cover) (1)
Operating Temp (w/ cover) (1)
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Weight (Typ)
Size (WxHxD)
Warranty
HK10A
A
%
ms
g
in
-
HK15A
HK25A
HK50A
HK100A
HK150A
85 - 132VAC (47 - 440Hz) or 110 - 175VDC
20
30
15
30
15
15
1% (over operating temperature range)
>105%
>115% (Zener clamp)
115 to 135%
20
No
Yes
Green LED = On
0°C to +60°C, derate linearly to 50% load from 50°C to 60°C
0°C to +50°C, derate linearly to 50% load from 40°C to 50°C
-30 to +85°C
30 - 90% RH (non condensing)
10 - 95% RH (non condensing)
Convection cooled
I/P to Grnd, I/P to O/P 2kVAC (20mA), O/P to Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1 m/s2
UL60950-1, CSA C22.2 No. 60950-1 (cUL)
FCC Class B, VCCI-B
RSEL-20R5W
RSEL-2001W
RSEL-2002W
RSEN-2006
150
170
230
280
540
650
2.83x2.83x1.02 2.83x3.31x1.08 2.83x3.9x1.26 2.83x4.69x1.38 3.66x5.91x1.52 3.66x6.69x1.85
Three Years
(1) Vertical mount as photo, HK100A & HK150A models operate to -10°C
See installation manual for full details, test methods of parameters and application notes
1-800-526-2324 • www.us.tdk-lambda.com/lp/
9