POWER
LPS360-M Series
360 Watt AC-DC Power Supply
Low Power Data Sheet
Total Power: 200 - 360 W
Input Voltage: 90 - 264 Vac
120 - 300 Vdc
Outputs: Single
SPECIAL FEATURES
Medical and ITE safeties
Active power factor correction
3” x 5” footprint
Less than 1U high
EN61000-3-2 compliant
Remote sense
Power fail
Adjustable main output
Level B Conducted EMI - Class I
or Class II inputs
Electrical Specifications
Input
Input range:
90 - 264 Vac; 120 - 300 Vdc
Overvoltage protection
Frequency:
47 - 63 Hz
Overload protection
Inrush current:
50 A max., cold start @ 25 °C
Thermal overload protection
Efficiency:
Up to 93% at full load
12 V fan output
EMI/RFI:
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Power factor:
0.99 typical
Remote Inhibit
Safety ground leakage
current:
150 uA @ 132 Vac, 60 Hz for class I, 300 uA @ 264 Vac, 60 Hz for class II
PMBus commands
Output
Digital I2C interface
Maximum power:
200 - 240 W (see de-rating) for convection, 360 W with 400 LFM of forced air
Class I and Class II approved
Adjustment range:
12 V and 24 V models, -0%, +15%, 15 V and 48 V models, -5%, +10%
Standby output:
5 V @ 1A convection, 2 A with forced air
Fan output:
12 V @ 0.5 A convection, 1 A forced air
Hold-up time:
20ms @240W, 220Vac input; 12ms @ 360 W
Overload protection:
Short circuit protection on all outputs. Case overload protected @ 110 - 160%
above rating
15 - 50% above nominal output
LPX200 enclosure kit available
5 V Standby output
Dual AC fuses
Suitable for BF Type applications
SAFETY
TUV
60950, 60601-1
UL
60950, 60601-1
Overvoltage protection:
cULus
60950, 60601-1
Logical Control
CB
Certificate & report
Power failure:
CE
Mark (LVD & EMC)
Open collector logic signal goes high 100 - 500 msec after main output;
it goes low at least 6 msec before loss of regulation
Remote sense:
C
ompensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
CCC Approval