G6S
Surface-mounting Relay
Surface-mounting, double-pole
signal switching Relay, with
terminals jutting out from both sides
of the case
• Long terminals for ideal for soldering and mounting reliability. (Surface
mounting terminal models)
• Space-saving inside-L terminal. (Surface mounting terminal models)
• Unique terminal construction allowing the terminal temperature to rise
easily, ideal for soldering reliability. (Surface mounting terminal models)
• High dielectric strength (2,000 VAC) and impulse withstand voltage
between coil and contacts (2,500 V, 2 × 10 μs: Telcordia requirements).
• High sensitivity with 140 mW rated power consumption.
• Ultra-miniature at 9.4 mm (H) × 7.5 mm (W) × 15 mm (L).
• Applicable to IRS using heat-resistant material.
• Standard model conforms to UL/CSA standards.
• Model with PCB terminals (G6S@-2) is added to this series.
• BSI (EN60950) certified models available. (-Y type)
G
6
S
RoHS Compliant
■Model Number Legend
■Application Examples
G6 S @ - @ @ - @
1
2 3
•
•
•
•
4
3. Terminal Shape
None : PCB terminals
F : Outside-L surface mounting terminals
G : Inside-L surface mounting terminals
4. Approved Standards
None : UL, CSA
Y : UL, CSA, BSI (EN60950)
1. Relay Function
None : Single-side stable
U : Single-winding latching
K : Double-winding latching
2. Number of poles/
Contact form
2: 2-pole/DPDT (2c)
Telecommunication equipment
Measurement devices
Office automation machines
Audio-visual products.
■Ordering Information
●Surface mounting terminal standard models
Relay Function
Enclosure rating
Contact form
Single-side stable
Model
Rated coil voltage
Single-winding latching
Model
Rated coil voltage
Double-winding latching
Model
Rated coil voltage
3 VDC
G6S-2F
G6S-2G
Fully sealed
3 VDC
3 VDC
4.5 VDC
4.5 VDC
4.5 VDC
5 VDC
G6SU-2F
G6SU-2G
5 VDC
G6SK-2F
G6SK-2G
5 VDC
12 VDC
12 VDC
12 VDC
24 VDC
DPDT (2c)
Minimum packing unit
24 VDC
24 VDC
50 pcs/tube
(400 pcs/reel)
5 VDC
G6S-2F-Y
G6S-2G-Y
12 VDC
−
−
−
−
24 VDC
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6S-2F 3 VDC
Rated coil voltage
Note 2.When ordering tape packing, add -TR" to the model number.
Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.
Note 3.When ordering tape packing, minimum order unit is 2 reels (400pcs × 2 = 800 pcs).
1
G6S
Surface-mounting Relay
■Characteristics
Item
Relay Function
Single-side Stable
G6S-2, G6S-2F,
G6S-2G
Single-winding Latching
Double-winding Latching
G6SU-2, G6SU-2F,
G6SK-2, G6SK-2F,
G6SU-2G
G6SK-2G
75 mΩ max.
4 ms max.
4 ms max.
−
10 ms
1,000 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1
2,000 VAC, 50/60 Hz for 1 min
min
1,500 VAC, 50/60 Hz for 1 min
1,500 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1
−
min
Contact resistance *1
Operate (set) time
Release (reset) time
Min. set/reset pulse width
Insulation resistance *2
Between coil and contacts
Between contacts of different polarity
Between contacts of the same polarity
Dielectric
strength
Between set and reset coil
2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)
Between coil and contacts
Impulse
withstand
voltage
Vibration
resistance
Shock
resistance
Durability
EN60950 certified
G6S-2F-Y, G6S-2G-Y,
G6S-2-Y
−
2,000 VAC, 50/60 Hz for 1
min
−
2,500 V (2 × 10 μs);
1,500 V (10 × 160 μs)
1,500 V (10 × 160 μs)
2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)
1,500 V (10 × 160 μs)
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)
1,000 m/s2
750 m/s2
100,000,000 operations min. (at 36,000 operations/hr)
100,000 operations min. for AC (at 1,800 operations/h with rated load)
100,000 operations min. for DC (at 1,200 operations/h with rated load)
10 μA at 10 m VDC
-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation) only for
double-winding latching 24 VDC type and EN60950 standard approved 24 VDC type
5% to 85%
Approx. 2 g
Between contacts of different polarity
Between contacts of the same polarity
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
G
6
S
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except
between the set and reset coil).
*3. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating conditions, expected
reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions.
■Engineering Data
7
5
3
AC resistive load
1
500
Maximum voltage (%)
10
300
30 VDC resistive load
Ambient temperature 23°C
Switching frequency: 1,200
operations/h
100
50
0.3
0.1
10
30
1
0
300 500 700 1,000
150
250
G6SU
200
150
G6SK
12 VDC max.
5 125 VAC resistive load
Ambient temperature 23°C
3 Switching frequency: 1,800 operations/h
50 70 100
200
G6S
24 VDC
G6S-Y
G6S-Y
12 VDC max. 24 VDC
100
10
DC resistive load
G6S
4.5 to 12 VDC
30
0.7
0.5
250
●Ambient Temperature
vs. Maximum Voltage
(Latching)
Maximum voltage (%)
●Ambient Temperature
vs. Maximum Voltage
(Single-side Stable)
●Durability
G6S-2F(G)
Durability (×104 operations)
Switching current (A)
●Maximum Switching
Capacity
0.5
1
1.5
Switching voltage (V)
2
50
50
2.5
0
−40
3
G6SK
24 VDC
100
−20
0
20
40
60
80
0
−40
100
−20
0
20
40
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
Switching current (A)
Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil.
G6S
12 VDC max.
3
G6SU 12 VDC max.
2
G6SU 24 VDC
G6SK
12 VDC max.
G6S-Y
24 VDC
1
100
Y
1,000
X
min.
40
50
60
70
90
100
Ambient temperature (°C)
0
40
50
60
80
90
100
Ambient temperature (°C)
De400 energized
Z
1,000
200
200
40
20
70
600
X
1,000
60
Must operate voltage
Must release voltage
80
Energized
800
max.
80
max.
X
min.
G6SK 24 VDC
●Shock Malfunction
G6S-2F(G)
Sample: G6S-2F
Number of Relays: 10 pcs
1
G6S
24 VDC
G6S-Y
12 VDC max.
0
On the basis of rated voltage (%)
3
2
●Ambient Temperature
vs. Must Operate or Must
Release Voltage
G6S-2F(G)
●Ambient Temperature
vs. Switching Current
(Latching)
Switching current (A)
Switching current (A)
●Ambient Temperature
vs. Switching Current
(Single-side Stable)
0
−60
−40 −20
0
20
40
60
80
100 120
Ambient temperature (°C)
1,000
Z'
Shock direction
X
X'
Y
Z
Z'
400
1,000
X'
600
800
1,000
Y'
Unit: m/s2
Sample: G6S-2F
Number of Relays: 10 pcs
Y'
Conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each
with and without energizing the
Relays to check the number of
contact malfunctions.
3