SERIES KDA
ENGINEERING DATA SHEET
RELAY - NONLATCH
3 PST/NO +AUX, 25 AMP
All welded construction
3 PST configuration with 1 PDT, 2
AMP auxiliary contacts in one inch
cube
Contact arrangement
Designed to the
performance standards of
MIL-PRF-6106
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
28 Vdc and 115/200 Vac, 400 Hz, 3Ø
Weight
0.188lb max
Dimensions
1.01in x 1.01in x 1.00in
Hermetically sealed, corrosion resistant metal can.
Detail specifications and ordering data appear on the following
pages.
APPLICATION NOTES:
102
007
Contact factory for information on MIL-qualified part numbers.
APPLICABLE SOCKET:
SO-1061-8916
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating
per pole and load
type [1]
Resistive [2]
Inductive [3]
Motor
Lamp
Overload
Rupture
Load current in Amp
@28 Vdc
@115 Vac
400 Hz
@115/200 Vac
400 Hz, 3Ø
@115/200 Vac
60 Hz, 3Ø [9]
@230/400 Vac
400 Hz [11]
25
12
10
5
50
60
25
15
10
5
80
100
25
15
10
5
80
100
2.5
2.5
2
1
N/A
N/A
5
5
2
2
N/A
N/A
Contact rating of auxiliary contacts
at 28 Vdc or 115 Vac 400 Hz
Featuring LEACH© power and control solutions
www.esterline.com
Resistive
2 Amp
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Inductive
1 Amp
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
Lamp
0.5 Amp
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 07/10
- 167 -
Page 1 of 4