Current Transducer HAS 50 .. 600-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 50 .. 600 A
Electrical data
Type
Primary nominal Primary current, RoHS since
current rms
measuring range 1) date code
IPN (A)
IPM (A)
HAS 50-S
50
± 150
45217
HAS 100-S
100
± 300
45325
HAS 200-S
200
± 600
45166
HAS 300-S
300
± 900
45326
HAS 400-S
400
± 900
45333
HAS 500-S
500
± 900
45201
HAS 600-S
600
± 900
45260
VC
Supply voltage (± 5 %) 1)
± 15
V
IC
Current consumption
± 15
mA
RIS
Isolation resistance @ 500 VDC
> 1000
MΩ
VOUT Output voltage (Analog) @ ± IPN, RL =10 kΩ, TA = 25°C ± 4V ± 40
mV
ROUT Output internal resistance
approx
100
Ω
RL
Load resistance 2)
> 1
kΩ
Accuracy - Dynamic performance data
X
Accuracy @ IPN , TA = 25°C (excluding offset)
< ± 1
%
Linearity error 3) (0 .. ± IPN)
< ± 1
% of IPN
L
VOE
Electrical offset voltage, TA = 25°C
< ± 20
mV
VOH Hysteresis offset voltage @ IP =0,
after an excursion of 1 x IPN < ± 20
mV
TCVOE Temperature coefficient of VOE
HAS 50-S
< ± 2
mV/K
HAS 100 .. 600-S < ± 1
mV/K
TCVOUT Temperature coefficient of VOUT (% of reading)
< ± 0.1
%/K
tr
Response time to 90 % of IPN step
< 3
µs
di/dt di/dt accurately followed
> 50
A/µs
BW
Frequency bandwidth (- 3 dB) 4)
DC .. 50
kHz
ε
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
approx
Standards 5)
- 10 .. + 80
°C
- 25 .. + 80
°C
60
g
EN 50178: 1997
Features
●● Hall effect measuring principle
●● Galvanic isolation between
primary and secondary circuit
●● Isolation voltage 3000 V
●● Low power consumption
●● Extended measuring range
(3 x IPN)
●● Insulated plastic case made of
polycarbonate PBT recognized
according to UL 94-V0.
Advantages
●● Easy mounting
●● Small size and space saving
●● Only one design for wide current
ratings range
●● High immunity to external
interference.
Applications
●● AC variable speed drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Page 1/3
090914/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com