(1/2)
EMC Filters for AC Power Line
Inlet-socket Type ZUB.U-22, ZUB.D-22 Series
FEATURES
• Either single fuse filters(U type) or double fuse filters(D type).
• Internal fuse simplifies maintenance(Without spare fuse).
• Leakage current is maintained below 0.01mA.
• Uses Faston® #250 output terminals, simplifying handling and
maintenance, and permitting soldering.
• It is a product conforming to RoHS directive.
Conformity to RoHS Directive
SAFETY STANDARDS
Standard and standard No.
U.S.A.
Canada
Part No.
UL(NRTL)
UL1283
1061287
1061287
ZUB22XXU-22
ZUB22XXD-22
Europe
CSA
NEMKO
CSA C22.2 No.8
LR76849C
LR76849C
EN60939
P08209030
P08209030
APPLICATIONS
Computer terminals, various types of office automation equipment,
digital devices(ECRs, etc.), measurement equipment, medical
equipment, etc.
SHAPES AND DIMENSIONS
Typical dimensions for installation
From front panel
ø3.6 or M3 tap
R3.5
øH
C
F
36
30.2
36
27.8
A
D
G
From back side panel
ø3.6
R2
E
B
30.8
33
• Tighten the panel mounting M3 dia. bolt with the torque under 5.88X10–1N • m.
Dimensions in mm
Series
A
B
C
D
ZUB-U-22
44
59
37
36
ZUB-D-22
44
68
37
36
• Case:metal, input terminal:inlet-socket(EN60320), output terminal: Faston® #250(t:0.8mm)
E
41
41
F
6
15
G
27
27
øH
3.5
3.5
ELECTRICAL CHARACTERISTICS
Part No.
Rated voltage Eac (V)
Rated current (A)
Test voltage Eac (V) [Between terminal and ground terminal]
Insulation resistance (MΩ)
[DC.500V, 1min/between terminal and ground terminal]
Leakage current (mA) [250V • 60Hz]
DC resistance (mΩ)
Operating temperature range (° C)[Including self-temperature rise]
With derating over(°C)
Temperature rise (° C)
Differential mode
Attenuation frequency range
(MHz) [+5 to +35° C]
Common mode
Weight (g)
ZUB2203U-22
250
3
1500
ZUB2206U-22
250
6
1500
ZUB2210U-22
250
10
1500
100min.
100min.
100min.
0.01max.
150max.
–25 to +85
55
30max.
0.6 to 8[20dB]
0.4 to 8[20dB]
71
0.01max.
100max.
–25 to +85
55
30max.
0.6 to 10[20dB]
0.8 to 4[20dB]
71
0.01max.
70max.
–25 to +85
55
30max.
0.6 to 10[15dB]
1 to 20[10dB]
71
Part No.
Rated voltage Eac (V)
Rated current (A)
Test voltage Eac (V) [Between terminal and ground terminal]
Insulation resistance (MΩ)
[DC.500V, 1min/between terminal and ground terminal]
Leakage current (mA) [250V • 60Hz]
DC resistance (mΩ)
Operating temperature range (° C)[Including self-temperature rise]
With derating over(°C)
Temperature rise (° C)
Differential mode
Attenuation frequency range
(MHz) [+5 to +35° C]
Common mode
Weight (g)
ZUB2203D-22
250
3
1500
ZUB2206D-22
250
6
1500
ZUB2210D-22
250
10
1500
100min.
100min.
100min.
0.01max.
150max.
–25 to +85
55
30max.
0.6 to 8[20dB]
0.4 to 4[20dB]
76
0.01max.
100max.
–25 to +85
55
30max.
0.6 to 10[20dB]
0.8 to 4[20dB]
76
0.01max.
70max.
–25 to +85
55
30max.
0.6 to 10[15dB]
1 to 20[10dB]
76
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
003-01 / 20080818 / e9173_zub_22.fm